Veterinarian Advanced Digital Radiographic (DR) X-Ray

 

The Sterne Medical Veterinarian System features digital radiography (DR), a high frequency generator, and a 4 way float table. It is an affordable complete Digital Radiography (DR) solution with superior quality.

 

Features/Specifications:

 

- Height = 31 inches

- Length = 60 inches

- Width = 28 inches

- Cross Table Travel = 8 inches

- Longitudinal Table Travel = 14 inches

- Space Requirement = 6 x 9 feet

- Vertical SID Fixed 40 inches.

Vet Eco21 table

Standard DR Specifications:

 

 

Detector Type: 16 Mega Pixel KODAK extreme KAF series CCD Detector Chip.
Optical Specification: Exclusive Leading Edge Optical Array with Breakthrough Light Transfer and Distortion Elimination Capability Using NO Mirrors.
Resolution: 4096 x 4096 Pixels Overall Imaging Resolution. Minimum 4.6 Line Pair per mm Resolution.
Acquisition Time: Approximately 3 to 5 Seconds From Exposure to Displayed Image.
Recycle Time: Zero Time Lag Between Subsequent Image Acquisitions.
Scintillation Screen: Cesium Iodide (CsI).
Active Image Area: 40.5 x 40.5 cm Active Area (43 x 43 cm Optional).
Operating Environment: Windows XP Based Acquisition and Review Software Module.
   DICOM Format: Full DICOM 3.0 “Push/Pull” Connectivity to HIS/RIS and Practice Management Systems. Easy to Burn CD with on Board Auto Launching Mini Viewer.


Digital Radiographic (DR) Options:

Sterne Medical provides comprehensive and affordable Digital Radiography (DR) solutions for all applications. The Sterne Medical DR units can be integrated into any Sterne Medical X-Ray system and can also retrofit into most other existing and/or new X-Ray equipment types.

 

Digital Radiography Detector Options:

 

SPECIFICATIONS: ADVANCED - CCD ULTRA - CCD
Detector Type: 9 Mega Pixel KODAK Extreme KAF Series CCD Detector Chip. 16 Mega Pixel KODAK Extreme KAF Series CCD Detector Chip.
Optical Specifications: Exclusive Leading Edge Optical Array with Breakthrough Light Transfer and Distortion Elimination Capability Using NO Mirrors.
Resolution: 3072 x 3072 Pixels Imaging Resolution. 
Minimum 4.3 Line Pair per mm Resolution.
4096 x 4096 Pixels Imaging Resolution.
Minimum 4.6 Line Pair  per mm Resolution.
Acquisition Time: Approximately 3 to 5 Seconds From Exposure to Displayed Image.
Recycle Time: Zero Time Lag Between Subsequent Image Acquisitions.
Scintillation Screen: Cesium Iodide (CsI).
Active Image Area: 40.5 x 40.5 cm Active Area (43 x 43 cm Optional).
DICOM Format: Full DICOM 3.0 "Push/Pull" Connectivity to HIS/RIS and Practice Management Systems.
  ADVANCED - FLAT PANEL ULTRA - FLAT PANEL
 
Detector Type: a-Si (Amorphous Silicone) Based TFT/TFT (Thin Film Transistor) Type Receptor.
Scintillation Screen: Cesium Iodide (CsI).
Active Image Area: 33 x 28 cm Active Area (13 x 11 inches). 43 x 43 cm Active Area (17 x 17 inches).
Resolution: 3.8 Line Pair per mm Resolution. Minimum 3.7 (standard 4.0) Line Pair per mm Resolution.
Active Pixel Size / Matrix: 127 µm @ 2520 X 2040 143 µm @ 3072 x 3072
DICOM Format: Full DICOM 3.0 "Push/Pull" Connectivity to HIS/RIS and Practice Management Systems. DICOM 3.0 MINIPACS “Push/Pull” and Work List Module for HIS/RIS and PMS Connectivity.

 

Computer Workstation Minimum Required Specifications:

 

- Leading Edge Intel CPU

- 4 GB High Speed RAM

- 1 TB Hard Disk Drive @ 7200 RPM

- Independent PCI Video Graphics Card (1 GB Minimum) and Dedicated Image

  Processing Electronics.

- DVD/CD Drive @ 16 RW with Nero + BURN

- Windows XP Professional Operating System

 

Monitor Minimum Required Specifications:

 

- 2 MB High Contrast 1600 x 1200

- 21 inch Display

 


 

Generator Specifications:

 

20 or 30 KW High Frequency Generator with Anatomical Programs.
Generator Console

- Higher frequency for reduced radiation

  exposure.

- Separate generator cabinet and 

  operator's console

- Tube protection circuit.

- Compact high voltage transformer is

  fitted in the generator cabinet.

- Optional APR (easy preset

  techniques by anatomical region

  selection) operator console.

- Optional AEC (automatic exposure

  console).

- Optional Buckey Control.

 

Specs  HF
Output Power Technique Factors 20 or 30 kW
400 mA, 125 kVp
mA Range
kVp Range
Time
25 to 400 mA
40 to 125 kVp
2ms to 6 sec.
Input Power Single Phase 188/250 VAC
65A Breaker
Weight (Cabinet) 150lb (68kg)

 

 

     
Sterne Medical
20 Strathearn Avenue Unit #4
Brampton, Ontario, Canada L6T 4P7
Tel:  1-905-457-2524
Fax:  1-905-457-3396