Veterinarian Advanced Digital Radiographic
(DR) X-Ray

The Sterne Medical Veterinarian System features digital radiography
(DR), a high frequency generator, and a 4 way float table. It is
an affordable complete Digital Radiography (DR) solution with
superior quality.
|
Features/Specifications:
- Height = 31 inches
- Length = 60 inches
- Width = 28 inches
- Cross Table Travel = 8 inches
- Longitudinal Table Travel = 14
inches
- Space Requirement = 6 x 9 feet
- Vertical SID Fixed 40 inches.
|
 |
|
Standard
DR Specifications:
|
|
| Detector Type: |
16 Mega Pixel KODAK extreme KAF
series CCD Detector Chip. |
| Optical
Specification: |
Exclusive Leading Edge Optical Array
with Breakthrough Light Transfer and Distortion
Elimination Capability Using NO Mirrors. |
| Resolution: |
4096 x 4096 Pixels Overall Imaging
Resolution. Minimum 4.6 Line Pair per mm Resolution. |
| Acquisition
Time: |
Approximately 3 to 5 Seconds From
Exposure to Displayed Image. |
| Recycle Time: |
Zero Time Lag Between Subsequent
Image Acquisitions.
|
| Scintillation
Screen: |
Cesium Iodide (CsI). |
| Active Image
Area: |
40.5 x 40.5 cm Active Area (43 x 43
cm Optional). |
| Operating
Environment: |
Windows XP Based Acquisition and
Review Software Module. |
|
DICOM Format: |
Full DICOM 3.0 “Push/Pull”
Connectivity to HIS/RIS and Practice Management Systems.
Easy to Burn CD with on Board Auto Launching Mini
Viewer. |
Digital Radiographic (DR) Options:
Sterne Medical provides comprehensive and affordable
Digital Radiography (DR) solutions for all applications. The
Sterne Medical
DR units can be integrated into any Sterne Medical X-Ray system and can
also retrofit into most other existing and/or new X-Ray equipment
types.
Digital Radiography Detector Options:
|
SPECIFICATIONS: |
ADVANCED
- CCD |
ULTRA - CCD |
|
|
 |
 |
| Detector Type: |
9 Mega Pixel
KODAK Extreme KAF Series CCD Detector Chip. |
16 Mega Pixel KODAK Extreme KAF
Series CCD Detector Chip. |
| Optical
Specifications: |
Exclusive Leading Edge
Optical Array with Breakthrough Light Transfer and
Distortion Elimination Capability Using NO Mirrors. |
| Resolution: |
3072 x 3072
Pixels Imaging Resolution.
Minimum 4.3 Line Pair per mm Resolution. |
4096 x 4096 Pixels Imaging
Resolution.
Minimum 4.6 Line Pair per mm Resolution. |
| Acquisition
Time: |
Approximately 3 to 5
Seconds From Exposure to Displayed Image. |
| Recycle Time: |
Zero Time Lag Between
Subsequent Image Acquisitions. |
| Scintillation
Screen: |
Cesium Iodide (CsI). |
| Active Image
Area: |
40.5 x 40.5 cm Active
Area (43 x 43 cm Optional). |
| DICOM Format: |
Full DICOM 3.0
"Push/Pull" Connectivity to HIS/RIS and Practice
Management Systems. |
| |
ADVANCED
- FLAT PANEL |
ULTRA - FLAT PANEL |
|
|
 |
|
| Detector Type: |
a-Si (Amorphous
Silicone) Based TFT/TFT (Thin Film Transistor) Type
Receptor. |
| Scintillation
Screen: |
Cesium Iodide (CsI). |
| Active Image
Area: |
33 x 28 cm
Active Area (13 x 11 inches). |
43 x 43 cm Active Area (17 x 17
inches). |
| Resolution: |
3.8 Line Pair
per mm Resolution. |
Minimum 3.7 (standard 4.0) Line
Pair per mm Resolution. |
| Active Pixel
Size / Matrix: |
127 µm @ 2520 X
2040 |
143 µm @ 3072 x 3072 |
| DICOM Format: |
Full DICOM 3.0
"Push/Pull" Connectivity to HIS/RIS and Practice
Management Systems. |
DICOM 3.0 MINIPACS “Push/Pull” and
Work List Module for HIS/RIS and PMS Connectivity. |
Computer Workstation Minimum
Required Specifications:
- Leading Edge Intel CPU
- 4 GB High Speed RAM
- 1 TB Hard Disk Drive @ 7200 RPM
- Independent PCI Video Graphics Card (1 GB Minimum) and
Dedicated Image
Processing Electronics.
- DVD/CD Drive @ 16 RW with Nero + BURN
- Windows XP Professional Operating System
Monitor Minimum Required Specifications:
- 2 MB High Contrast 1600 x 1200
- 21 inch Display

Generator
Specifications:
20 or 30 KW High Frequency Generator with Anatomical Programs.
 |
- Higher frequency for
reduced radiation
exposure.
- Separate generator cabinet and
operator's console
- Tube protection circuit.
- Compact high voltage
transformer is
fitted in the generator cabinet.
- Optional APR (easy preset
techniques by anatomical region
selection) operator console.
-
Optional AEC (automatic exposure
console).
-
Optional Buckey Control.
|
| Specs |
HF |
| Output Power
Technique Factors |
20 or 30 kW
400 mA, 125 kVp |
mA Range
kVp Range
Time |
25 to 400 mA
40 to 125 kVp
2ms to 6 sec. |
| Input Power |
Single Phase
188/250 VAC
65A Breaker |
| Weight
(Cabinet) |
150lb (68kg)
|
|